- Advisory services
- Consultations
- Network and technology policies
- Network and technology service docs
- Using Jisc community
- Advisory services
- Multi-site Connectivity Advisory Service
- Video Technology Advisory Service
- Voice Advisory Service
- Wireless Technology Advisory Service
- Video Technology Advisory Service
- Planning rooms for videoconferencing
- Product evaluations
- Product evaluations
- CODEC summary table
- Desktop software for videoconferencing
- Product evaluation reports
- CODEC Test procedure
- USB echo cancellation results
- Product evaluation reports
- Cisco Telepresence SX80
- Clearone Collaborate Room Pro 600
- Vidyo HD40 and HD100
- Cisco SX10
- Starleaf GT Mini and PT Mini
- Huawei TE30
- AVer EVC130p
- Avaya XT5000 720
- Polycom Realpresence Group 500
- Lifesize Room 220/220i
- Polycom Realpresence Group 300
- AVer ClassHD
- Lifesize Icon 600
- Radvision XT5000
- Cisco Telepresence SX20 Quick Set
- AverComm HVC330
- Lifesize Team 220™
- Cisco Telepresence EX60
- LifeSize LG Executive
- LifeSize Passport
- PolyCom HDX 4500
- PolyCom HDX 6004
- PolyCom HDX 9004 (9000 - 720)
- Radvision Scopia VC240
- Radvision Scopia XT1000
- Tandberg C20
- Tandberg C40
- Radvision XT5000
- Executive Summary Radvision XT5000
- Manufacturer comments - Radvision Scopia XT5000
- Radvision XT5000 - Evaluation results main document
- Appendix 1 - Radvision XT5000 - Detailed physical information
- Appendix 2 - Radvision XT5000 - Detailed video test results
- Appendix 3 - Radvision XT5000 - Detailed audio test results
Appendix 3 - Radvision XT5000 - Detailed audio test results

Test 1: Frequency response (-3 dB)
(Insert -6 dB signal at local site, measure at remote site)
G.711 A law |
G.722.1 |
AAC-LD, |
G.719 |
4.2 KHz |
7.0 KHz |
14.5 KHz |
20.0 KHz |
Test 2: Headroom (measured on AAC-LD signal coding)
Insert increasing amplitude 1 KHz tone at local site, monitor for overload distortion at remote site
Overload occurs at: +9dBm
Test 3: Audio level
(Insert -6dBm 1KHz tone at local site, monitor received level at remote site.)
As the audio output level is affected by the volume control this test was not carried out.
Test 4: Echo Cancellation
Setup The echo canceller is fully automatic in operation. The quality of echo cancellation and doubletalk from the system was excellent.
Lecture Theatre |
Room |
|
Audio levels adequate? (Yes/no) |
Not tested |
Yes |
Audio quality acceptable? (Yes/no) |
Not tested |
Yes |
Echo cancellation acceptable? (Yes/no) |
Not tested |
Yes |
Quality of double talk |
Not tested |
Excellent |